Introduction

能檢查心血管硬化阻塞程度,令用家盡早發現疾病危機,,及時接受治療。準確性可膍美醫院級儀器 ,針對患有糖尿病及高血壓病患人仕。

Warranty Info

Distributor offers 2-year Hong Kong local warranty service.

Product Description


The World’s Only Portable Cardiovascular Measuring Instrument


PASESA possesses a medical measuring function which goes along with 13 items of patented technology from the US and Japan. It aims to help discover concealing cardiovascular diseases by doing a quick check on arteriosclerosis. It minimises the possibility of clients infected by more serious diseases. It is also well-linked with charts in order to analyse the AVI&API, blood pressure and pulse rate, so to maintain clients’ health stability. The device is especially suitable for policlinic since it is efficient and non-invasive even though it contains various functions.。



   

Non-Invasive Measurement

The entire measuring process of arteriosclerosis is fully automatic, efficient (takes approximately 1-2 minutes) and user friendly.

Cuff-Less Design

The cuff-less design of the device allows users to complete the measurement in a sitting position. With this device, it makes the whole process easier.

Visualised Analyzation

It uses built-in charts to analyse the AVI, API, blood pressure and pulse rate. All the records will be backed up in cloud storage as a support for better analyzation in future.

Patented Technology

It has possessed multiple international recognition of patents. Its high accuracy rate has been a guarantee of confidence to the clients.

Three Key Values


  • Prevention From Critical Illness
People with hyperglycemia, hyperlipidemia and hypertension stroke and cardiovascular diseases are able to monitor cardiovascular stiffness in advance, in order to prevent from critical illness such as stroke and heart disease.

  • Medicine Evaluation
PASESA can protect the ones who had been suffered from cardiovascular diseases such as stroke and heart disease from relapsing by monitoring medicine efficacy and progress of rehabilitation.

  • Clinic’s Screening
PASESA is commonly used in clinics and medical centres. It provides quick screening on the cardiovascular systems of people who are at high risk, any error state or abnormal condition can be discovered timely, so to prevent interrelated diseases from derivation.

Theory Of The Measurement


There is a significant association between arterial stiffness and cardiovascular diseases such as high blood pressure, coronary heart disease, kidney failure and cerebral apoplexy. Meanwhile, it is proved that vascular stiffness will rise along with the growth of the age. Therefore, measuring vascular stiffness will be apparently valuable in figuring out any cardiovascular diseases and preventing interrelated diseases from happening. PASESA has the function of measuring AVI and API. These two key indexes in measuring cardiovascular stiffness are proved by top graduate schools and institutes that it is highly interrelated with the prevention of cardiovascular diseases.(Read More)。

AVI

The figure AVI gets larger when the arteriosclerosis is getting more serious. Changes of pulse number and reflected wave caused by arteriosclerosis in the central artery can be shown by waveform analysis.Therefore, the softer the blood vessels are, the smaller the figure in AVI is, vice versa.

API

The figure API detects stiffness of axillary artery by taking in stiffness in the brachial artery. API serves like a monitor, the higher the stiffness, the higher API it shows, like it happens when specific pathologic factors such as high blood pressure and blood lipids lead to the rise in stiffness of peripheral arteries.


Patent and Authentication

PASESA’s Portable Arterial Pulse Wave Detector has possessed various measurement techonology updates. Its patent right is guaranteed by the United States Patent and Trademark Office, Japan Patent Office, State Intellectual Property Office of the P.R.C and China Food and Drug Administration.

Supports from Top Graduate Schools And Institutes


The significant association between AVI / API and cardiovascular diseases has been proved by the top graduate institutes, including The University of Tokyo, Tokyo Medical University, Yokohama National University and so on. Besides, the products are invented and developed jointly by the Institute of Physical and Chemical Research and the National Institute of Advanced Industrial Science and Technology. With all the support and contributions from these renowned institutes, PASESA has earned high recognition from the globe.


家用便攜式血管硬化量度儀原理

柔軟的血管會伴隨腕帶的減壓,動脈容量將急遽變化。將這個曲線傾斜程度加以指標化,便能把硬度數據化 ,令你們更了解自己身體狀況 。

Product Comparison





產品規格

尺寸: 180 X 266 X 260 mm
LCD 顯示屏: 55 X 90 mm TN類型
電源 (AC適配器) 輸入: AC100-240V 50-60 HZ
測量方法 : 示波測定法
測量範圍 : 壓力範圍 : 0~280mmHg (0~37.3kPa)
脈搏範圍 : 30~199次/分
AVI & API 範圍: 5~99
性能要求標準 : YY 0670-2008
操作環境 溫度 : 5~40 濕度 : 15%RH~80% RH 大氣壓 : 80kPa ~ 105kPa
重量: 約2.6kg (不含電池)
通信格 : NFC/藍4.0 BLE
電源 (電池) : AA (5號) 鹼性電X 4(請另行購買)
測量臂周 : 約19cm~32cm
測定精度 : 壓力+/-3 mmHg (0.4kPa)